4/8/16-channel H.264 DVR User Manual
25
3.7.6 PTZ
Enter the “PTZ” screen from “Main Menu” →“Advanced”, as shown below:
Channel: selecting the channel to which the dome camera is connected (to select any
of the latter 4 channels, click “Next Page”)
Protocol: selecting the dome protocol of the corresponding brand and model, with two
options, Pelco-D by default
Baud rate: selecting the baud rate used by the dome, with the 4 options of 1200, 2400,
4800 and 9600
Data bit: with the options of 5, 6, 7 and 8, 8 by default
Stop bit: with the options of 1 and 2, 1 by default
VERIFY: with the 5 options of None/Odd/Even/Mark/Space, None by default
Address : Complete the PTZ code of the corresponding channel.
Just set “protocol”, “baud rate” and “address code” in order to set the PTZ.
See “Shortcut Menu” →“PTZ Control” for PTZ control.
3.7.7 Network setup
Enter the “Network” screen from “Main Menu” →“Advanced”, as shown below:
TYPE: with 4 options: STATIC, DHCP, PPPOE and 3G.
STATIC : allocating an IP address manually.
DHCP: acquiring an IP address automatically.
After selecting the DHCP mode, restart the system after confirmation. After starting, the
system will establish a connection with the DHCP server automatically. When this is
successful, this unit will be allocated an IP address, which will be displayed on the
screen.